Blockmaster™ DB series
For
immunological
testsBlockmaster™CE510/CE210
Target Material
- Latex beads
- Magnetic beads (Material having a functional group capable of binding to the amino group)
- Colloidal gold particles
Mode of attachment
- Primary ・・・ Covalent coupling
- Secondary ・・・ Physical adsorption
For
immunological
testsBlockmaster™DB1130
Target Material
- Latex beads
- Magnetic beads
Mode of attachment
- Physical adsorption
Blocking agents
for multiple purposeBlockmaster™PA1080
Target Material
- Applicable to various materials and substrates (PSt, PP, COP, Glass, PDMS, PVDF, Nitro cellulose, etc)
Mode of attachment
- Physical adsorption
Synthetic blocking agent for latex particle
Blockmaster™ DB1130 is developed as surface blocking agents of latex particles. It can well suppress the unspecific binding of latex to enhance the stabiliy of colloid. The unique water-soluble polymer with the proper balance of hydrophobic unit and hydrophilic unit proposed by JSR can be used as a replacement of BSA.
Characteristic
- Can be used as an substitute blocking agent of the BSA or along with BSA
- Prevention of non-specific reactions caused by BSA or other proteins
- Improvement of beads dispersion
The flow of blocking with Blockmaster™ DB1130
The hydrophobic segement to hydrophilic segement ratio of Blockmaster™ DB1130 was modified to the best condition, so it can adsorb to the surface of covalently coupled latex beads to prevent the adsorption of substances that is not related to the immunoreaction and suppress the unspecific aggregation of latex.
Detail of product
Grade | Package Volume | Solid Content | Solvent | Shelf Life |
---|---|---|---|---|
DB1130 | 100 mL | 10% | Water + 0.005% Proclin 950 | Labeled on the bottle |
Grade | DB1130 |
Package Volume | 100 mL |
Solid Content | 10% |
Solvent | Water + 0.005% Proclin 950 |
Shelf Life | Labeled on the bottle |
※ There is also a 1000 mL package for raw materials for in vitro diagnostics. If you would like to purchase 1000 mL packaged product, please contact us.
Application
Colloidal stability
Latex blocked with Blockmaster™ DB1130 shows the equivalent colloidal stability to the one with BSA blocking, and the precipitation will not be occurred even with long-term storage.
Dose-response curves and lot-to-lot consistency
For the polyclonal antibody diagnostics, three batch of Blockmaster™ DB1130 was used for blocking, and the result shows that the quality is stable between different lots.
Polyclonal antibody item C of latex immunoassay
Dose-response curves and Response in different serums
Latex beads conjugated with monoclonal antibodies were treated with BSA or Blockmaster™ DB1130 and it was confirmed that the two treatment shows equivalent result.
Monoclonal antibody item G of latex immunoassay
Application in CLEIA; Dose-response curves and Correlation test of 31 specimens
The kit treated with Blockmaster™ DB1130 shows equivlent result to the kit with BSA blocking. Furthermore, 31 clinical samples are used for the correlation study. The result shows that two kinds of kits show good correlation.
STORAGE
Please store at 2-8℃. Do not freeze the bottle.